231 AuraFlame Masonry Fireplace

The AuraFlame is not only focused on style with its arched door design, but also on practicality. This assures you of a clean, thorough burn, and even allows you to control the amount of firewood burned. Available with either Black or Gold Plated cast iron doors.

STANDARD FEATURES
• 90,000 Btu’s
• 73% Efficiency
• Secondary Combustion System
• Air Seal Cast Iron Doors
• 8″ Clay Flue Adaptor
• 4″ Outside Air Flex Pipe
• Borofloat Safety Glass ( (2) 16½” x 11″)
• Chimney Damper Control
• Combustion Air Damper Control
• Ajustable Legs
• 20 Year Limited Warranty

OPTIONAL FEATURES
• Gold Plated Cast Iron or Black Cast Iron Arched Doors
• Black Upper and Lower Grills
• Brass Upper and Lower Grills
• Arched Face Trim – Brass
• Arched Door Trim – Brass
• Brick-in Fan w/ Variable Speed Control (450 CFM)
• Outside Combustion Air Vent
• Ash Chute & Cover
• Outside Clean Out Door
• Top Plate w/ Precut Center Hole
• Arched Lintel Iron
• 8″ Round Stack Pipe – Straight
• 5″, 10″ & 14 1/2″ Offset Stacks
• 8″ Round Metal Chimney Adaptor for use with 8″ HT, Class “A”, Metal Chimney

CLEARANCES
• From Unit Sides to Face brick: 3/8″
• From Unit Top to Face Brick: 1/2″
• From Unit Back/Sides to Block Enclosure: 4″
• From Block Enclosure to Exterior Walls: 4″
• From Top of Grill Opening to Ceiling: 17″
• From Fuel Door to Combustion Mantel: 16″
• From Fuel Door to Side Wood Mantel: 8″
• From Side of Fuel Opening to Adjacent Wall: 24″”
• From Top Slab to Wooden Header: 12″”
• YOU MUST Cover Top Slab w/ 6″ Non-Faced Fiberglass Insulation
• From Wooden Header to Chimney Block: 2″
• From 10″ Stack Pipe to Bottom of Top Slab: 1″

VENTING REQUIREMENTS
Always consult the installation manual for venting requirements

REQUIRED CHIMNEY TERMINATION
• 4″ Outside Air Flex Pipe Kit for Chamber only -(included w/ unit) (connects intake air on fireplace to 4″-30 gauge galv. pipe)
• 30 Gauge Galvanized Pipe (minimum thickness) (adapts 4″ flex pipe at chamber wall to outside air vent)
• Maximum Termination – 26′
• Runs up to 10′ – Pipe Size – 4″
• Runs Between 10′ – 26′ – Pipe Size – 6″
• Elbows – Maximum – 3
• Do Not Terminate into Attic or Garage
• 3′ Clearance Below Chimney if Terminating Beside Chase”

OUTSIDE AIR TERMINATION
• 8″, HT, Class “A”, 2100 , Insulated Double Wall Metal Chimney OR
• 9″ x 13″ Clay Flue
• Minimum Height – 10′
• 30 Angle Maximum Offsets