STANDARD FEATURES
• 130,000 Btu’s
• Black, Air-Seal, Square Cast Iron Doors (2)
• 73% efficient
• 10″ Clay Flue Adaptor
• 4″ Outside Air Flex Pipe
• Borofloat Safety Glass ( (2) 14½” x 17″)
• Chimney Damper Control
• Combustion Air Damper Control
• Adjustable Legs (for leveling unit)
• 10 Year Limited Warranty

OPTIONAL FEATURES
• Black Upper & Lower Grills
• Brass Upper & Lower Grills
• Face Trim – Brass
• Door Trim – Brass
• Fan Kit w/ variable speed control
• Outside Combustion Air Vent (closure & nonclosure)
• Ash Chute & Cover
• Outside Clean Out Door (for ash dump)
• Top Plate w/ Precut Ctr Hole/Straight Wall-Recessed Mantel
• 10″ Round Stack Pipe – Straight
• 44″ Lintel Iron
• 5″, 10″ & 14 1/2″ Offset Stacks
• 10″ Round Metal Chimney Adaptor for use with 10″ HT, Class “A” Metal Chimney

CLEARANCES
• From Unit Sides to Face brick: 3/8″
• From Unit Top to Face Brick: 1/2″
• From Unit Back/Sides to Block Enclosure: 4″
• From Block Enclosure to Exterior Walls: 6″
• From Top of Grill Opening to Ceiling: 17″
• From Fuel Door to Combustion Mantel: 21″
• From Fuel Door to Side Wood Mantel: 10″
• From Side of Fuel Opening to Adjacent Wall: 24″
• From Top Slab to Wooden Header: 12″
• YOU MUST Cover Top Slab w/ 6″ Non-Faced Fiberglass Insulation
• From Wooden Header to Chimney Block: 2″
• From 10″ Stack Pipe to Bottom of Top Slab: 1″

VENTING REQUIREMENTS

REQUIRED CHIMNEY TERMINATION
• 10″, HT, Class “A”, 2100 , Insulated Double Wall Metal Chimney OR
12″ x 12″ Clay Flue
• Minimum Height -10′
• 30 Angle Maximum Offsets
• Minimum 5″ Offset Required w/ Recessed Mantel

OUTSIDE AIR TERMINATION
• 6″ Outside Air Flex Pipe for Chamber only – (included w/ unit) (connects intake air on fireplace to 6″ – 30 ga. galv. pipe)
• Minimum Thickness – 30 Gauge Galvanized Pipe
• Elbows – Maximum – 3
• Do Not Terminate to Attic or Garage
• 3′ Clearance Below Chimney if Terminating Beside Chase
• Maximum Termination – 26′