fbpx

432 Masonry Fireplace

Uniquely ours! Our model #432 is the only masonry bay window fireplace in the industry. It has the same features and benefits as our other masonry fireplaces, but has a larger burn area for an even more impressive display of flame.

STANDARD FEATURES
• 130,000 Btu’s
• 73% efficiency
• Black, Air-Seal, Square Cast Iron Doors (4)
• 10″ Clay Flue Adaptor
• 6″ Outside Air Flex Pipe
• Borofloat Safety Glass ( (2) 14″ x 15″)
• Chimney Damper Control
• Combustion Air Damper Control
• Adjustable Legs (for leveling unit)
• Bay Lintel Iron & Support Legs

OPTIONAL FEATURES
• Black Upper & Lower Grills
• Brass Upper & Lower Grills
• Face Trim – Brass
• Door Trim – Brass
• Brick-in Fan w/ Variable Speed Control (450 CFM)
• Outside Air Vents (closure & nonclosure)
• Ash Chute & Cover
• Outside Clean Out Door (for ash dump
• Top Plate w/ Precut Ctr Hole/Straight Wall-Recessed Mantel
• 10″ Round Stack Pipe – Straight
• 5″, 10″ & 14 1/2″ Offset Stacks
• 10″ Round Metal Chimney Adaptor for use with 10″ HT, Class “A” Metal Chimney

CLEARANCES
• From Unit Sides to Face brick: 3/8″
• From Unit Top to Face Brick: 1/2″
• From Unit Back/Sides to Block Enclosure: 4″
• From Block Enclosure to Exterior Walls: 6″
• From Top of Grill Opening to Ceiling: 17″
• From Fuel Door to Combustion Mantel: 21″
• From Fuel Door to Side Wood Mantel: 10″
• From Side of Fuel Opening to Adjacent Wall: 24″
• From Top Slab to Wooden Header: 12″
• YOU MUST Cover Top Slab w/ 6″ Non-Faced Fiberglass Insulation
• From Wooden Header to Chimney Block: 2″
• From 10″ Stack Pipe to Bottom of Top Slab: 1″

VENTING REQUIREMENTS
Always consult the installation manual for venting requirements

CHIMINEY TERMINATION
• 10″, HT, Class “A”, 2100 , Insulated Double Wall Metal Chimney OR
12″ x 12″ Clay Flue
• Minimum Height -10′
• 30 Angle Maximum Offsets
• Minimum 5″ Offset Required w/ Recessed Mantel

OUTSIDE AIR TERMINATION
• 6″ Outside Air Flex Pipe for Chamber only – (included w/ unit) (connects intake air on fireplace to 6″ – 30 ga. galv. pipe)
• Minimum Thickness – 30 Gauge Galvanized Pipe
• Elbows – Maximum – 3
• Do Not Terminate to Attic or Garage
• 3′ Clearance Below Chimney if Terminating Beside Chase
• Maximum Termination – 26′

Comments are closed.